Search
OECD_TG_437_main
Research Service

Artificial Cornea(RhCE) OECD TG 492

6485€+
Research Service

Artificial Cornea(RhCE) OECD TG 492

  • Alternative to Animal Testing
    The RhCE test uses reconstructed human cornea tissue, providing an ethical, reliable alternative to animal testing by closely simulating human physiological responses.
  • Fast and Efficient Results
    This method delivers results quickly, reducing research timelines and costs. It uses the MTT assay to objectively assess irritation through cell viability measurements.
  • Internationally Trusted Standards
    Recognized under OECD TG 492 and aligned with UN GHS, the RhCE test is a globally accepted method for reliably assessing eye irritation, aiding regulatory compliance worldwide.

Price
Organism
Product Type
Tissue
Disease

Applications

OECD

Eye Irritation

KTR (Korea Testing & Research Institute)
Testimonials

Advancing Drug Development: KTR and Lambda Biologics Unite for GLP-Certified, Organoid-Based Alternative Testing

KTR established Korea's first Animal Alternative Testing Center and has built related facilities in the biopharmaceutical sector to provide an innovative research environment. Currently, toxicity evaluations required in the drug...

Description

Table of Contents

In vitro eye irritation test (OECD TG 492)

Reconstructed human Cornea-like Epithelium (RhCE) test method for identifying chemicals not requiring classification and labelling for eye irritation or serious eyedamage.

Eye irritation test – Artificial cornea

Using the human corneal-like epithelium (RhCE) model, which closely mimics the histological, morphological, biochemical, and physiological characteristics of the human corneal epithelium, the assessment of eye irritation (UN GHS Category 2) or severe eye damage (UN GHS Category 1) is conducted according to UN GHS guidelines.
This evaluation is utilized to assess the toxicity of testsubstances (compounds and mixtures) that do not require classification andlabeling for UN GHS Category 1 (UN GHS No Category).

Test Process

Step 01
Preculture

Medium 0.9ml 37°C, 5% CO2, 22±2hours
Step 02
Test sample treatment

Liquide: 40μl. 10min Solid: DPBS 40μl + 40mg, 37°C, 5% CO2, 3hours
Step 03
Wash

Washing the inside and outside of the human cornea model with DPBS
Step 04
Post-culture

Medium 0.9ml 37°C, 5% CO2, 16±1hour
Step 05
WST-1 assay

WST-1 solution 300μl (insert inside 100μl, insert outside 200μl) 37°C, 5% CO2, 3hours±5min
Step 06
Absorbance Measurement

Supernant 200μl / well(96 well plate) 450nm

Read out